Plasma-Lyte A
Plasma-Lyte A is an FDA drug label for the active ingredient SODIUM CHLORIDE, SODIUM GLUCONATE, SODIUM ACETATE, POTASSIUM CHLORIDE AND MAGNESIUM CHLORIDE manufactured by Baxter Healthcare Corporation administered by INTRAVENOUS. This page reproduces the FDA-approved indications and usage, dosage, contraindications, warnings, and adverse reactions exactly as published in the drug label. Data source: openFDA (U.S. FDA), label effective 20190805.
- Generic name
- SODIUM CHLORIDE, SODIUM GLUCONATE, SODIUM ACETATE, POTASSIUM CHLORIDE AND MAGNESIUM CHLORIDE
- Manufacturer
- Baxter Healthcare Corporation
- Product type
- HUMAN PRESCRIPTION DRUG
- Route
- INTRAVENOUS
- Dosage form
- N/A
- NDC
- 0338-0221
- Application
- NDA017378
- Label effective
- 20190805
Indications & Usage
INDICATIONS AND USAGE PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is indicated as a source of water and electrolytes or as an alkalinizing agent.
Dosage & Administration
DOSAGE AND ADMINISTRATION Important Administration Instructions • PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is intended for intravenous administration using sterile equipment. • Do not connect flexible plastic containers in series in order to avoid air embolism due to possible residual air contained in the primary container. • Set the vent to the closed position on a vented intravenous administration set to prevent air embolism. • Use a dedicated line without any connections to avoid air embolism. • Do not pressurize intravenous solutions contained in flexible plastic containers to increase flow rates in order to avoid air embolism due to incomplete evacuation of residual air in the container. • Prior to infusion, visually inspect the solution for particulate matter and discoloration. The solution should be clear and there should be no precipitates. Do not administer unless solution is clear, and container is undamaged. • PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is compatible with blood or blood components. It may be administered prior to or following the infusion of blood through the same administration set (i.e., as a priming solution), added to or infused concurrently with blood components, or used as a diluent in the transfusion of packed erythrocytes. PLASMA-LYTE A Injection and 0.9% Sodium Chloride Injection, USP are equally compatible with blood or blood components. Dosing Information The choice of product, dosage, volume, rate, and duration of administration is dependent upon the age, weight and clinical condition of the patient and concomitant therapy, and administration should be determined by a physician experienced in intravenous fluid therapy. Introduction of Additives Additives may be incompatible. Evaluate all additions to the plastic container for compatibility and stability of the resulting preparation. Consult with a pharmacist, if available. If, in the informed judgment of the physician, it is deemed advisable to introduce additives, use aseptic technique. Mix thoroughly when additives have been introduced. After addition, if there is a discoloration and/or the appearance of precipitates, insoluble complexes or crystals, do not use. Do not store solutions containing additives. Discard any unused portion.
Contraindications
CONTRAINDICATIONS PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is contraindicated in patients with a known hypersensitivity to the product. See WARNINGS .
Warnings
WARNINGS Hypersensitivity Reactions Hypersensitivity and infusion reactions have been reported with PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP). See ADVERSE REACTIONS . Stop the infusion immediately if signs or symptoms of a hypersensitivity reaction develop, such as tachycardia, chest pain, dyspnea and flushing. Appropriate therapeutic countermeasures must be instituted as clinically indicated. Electrolyte Imbalances Fluid Overload Depending on the volume and rate of infusion, the intravenous administration of PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) can cause electrolyte disturbances such as overhydration, and congested states, including pulmonary congestion and edema. Avoid PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in patients with or at risk for fluid and/or solute overloading. If use cannot be avoided, monitor fluid balance, electrolyte concentrations, and acid base balance, as needed and especially during prolonged use. Hyponatremia PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) may cause hyponatremia. Hyponatremia can lead to acute hyponatremic encephalopathy characterized by headache, nausea, seizures, lethargy, and vomiting. Patients with brain edema are at particular risk of severe, irreversible and life-threatening brain injury. The risk of hospital-acquired hyponatremia is increased in patients with cardiac or pulmonary failure, and in patients with non-osmotic vasopressin release (including SIADH) treated with high volume of hypotonic PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP). Avoid PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in hypervolemic or overhydrated patients. If use cannot be avoided, monitor serum sodium concentrations. Hypernatremia Hypernatremia may occur with PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP)). Conditions that may increase the risk of hypernatremia, fluid overload and edema (central and peripheral), include patients with: primary hyperaldosteronism; secondary hyperaldosteronism associated with, for example, hypertension, congestive heart failure, liver disease (including cirrhosis), renal disease (including renal artery stenosis, nephrosclerosis); and pre-eclampsia. Certain medications, such as corticosteroids or corticotropin, may also increase risk of sodium and fluid retention, see PRECAUTIONS . Avoid PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in patients with, or at risk for, hypernatremia. If use cannot be avoided, monitor serum sodium concentrations. Hypermagnesemia Avoid solutions containing magnesium including PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in patients with or predisposed to hypermagnesemia, including patients with severe renal impairment and those patients receiving magnesium therapy (e.g., treatment of eclampsia and myasthenia gravis). PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is not indicated for the treatment of hypomagnesemia. Acidosis PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is not for use for the treatment of lactic acidosis or severe metabolic acidosis in patients with severe liver and/or renal impairment. Alkalosis Excess administration of PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) can result in metabolic alkalosis. Avoid PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in patients with alkalosis or at risk for alkalosis. PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) is not indicated for the treatment of hypochloremic hypokalemic alkalosis. Avoid use in patients with hypochloremic hypokalemic alkalosis. Hypocalcemia PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) contains no calcium, and an increase in plasma pH due to its alkalinizing effect may lower the concentration of ionized (not protein-bound) calcium. Avoid PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in patients with hypocalcemia. Hyperkalemia Potassium-containing solutions, including PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) may increase the risk of hyperkalemia. Patient’s at increased risk of developing hyperkalemia include those: • With conditions predisposing to hyperkalemia and/or associated with increased sensitivity to potassium, such as patients with severe renal impairment, acute dehydration, extensive tissue injury or burns, certain cardiac disorders such as congestive heart failure. • Treated concurrently or recently with agents or products that cause or increase the risk of hyperkalemia (see PRECAUTIONS ). Avoid PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) in patients with, or at risk for hyperkalemia. If use cannot be avoided, monitor serum potassium concentrations. Although PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) has a potassium concentration in plasma, it is insufficient to produce a useful effect in case of severe potassium deficiency; therefore, it is not indicated for correction of severe potassium deficiency.
Adverse Reactions
ADVERSE REACTIONS Post-Marketing Adverse Reactions The following adverse reactions associated with the use of PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) were identified in clinical trials or postmarketing reports. Because postmarketing reactions were reported voluntarily from a population of uncertain size, it is not always possible to estimate their frequency, reliably, or to establish a causal relationship to drug exposure. Hypersensitivity and Infusion Reactions : tachycardia, chest pain, chest discomfort, dyspnea, flushing, hyperemia, asthenia, pyrexia, hypotension, wheezing, urticaria, cold sweat, chills. General Disorders and Administration Site Conditions : infusion site pain, burning sensation. Metabolism and nutrition disorders : hyperkalemia, hyponatremia. Nervous System Disorders : hyponatremic encephalopathy. Overdose Excessive administration of PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP) can cause: • fluid overload with a risk of edema (peripheral and/or pulmonary), particularly when renal sodium excretion is impaired. • hypernatremia and hyperkalemia, especially in patients with severe renal impairment. • hypermagnesemia. See WARNINGS and ADVERSE REACTIONS • metabolic alkalosis with or without hypokalemia and decreased ionized serum calcium and magnesium concentrations. When assessing an overdose, any additives in the solution must also be considered. The effects of an overdose may require immediate medical attention and treatment. Interventions include discontinuation of PLASMA-LYTE A Injection pH 7.4 (Multiple Electrolytes Injection, Type 1, USP), dose reduction, and other measures as indicated for the specific clinical constellation (e.g., monitoring of fluid balance, electrolyte concentrations and acid base balance).