Pentam 300

PENTAMIDINE ISETHIONATE INTRAMUSCULAR HUMAN PRESCRIPTION DRUG

Pentam 300 is an FDA drug label for the active ingredient PENTAMIDINE ISETHIONATE manufactured by Fresenius Kabi USA, LLC administered by INTRAMUSCULAR. This page reproduces the FDA-approved indications and usage, dosage, contraindications, warnings, and adverse reactions exactly as published in the drug label. Data source: openFDA (U.S. FDA), label effective 20220913.

Generic name
PENTAMIDINE ISETHIONATE
Manufacturer
Fresenius Kabi USA, LLC
Product type
HUMAN PRESCRIPTION DRUG
Route
INTRAMUSCULAR
Dosage form
N/A
NDC
63323-113
Application
NDA019264
Label effective
20220913

About this product

Pentam 300 is an FDA-registered drug product whose active ingredient is PENTAMIDINE ISETHIONATE. It is labelled by Fresenius Kabi USA, LLC taken by intramuscular and marketed as a human prescription drug product. Identifiers on file: NDC 63323-113, application NDA019264, label effective 20220913. It is one of 3 FDA drug label records sharing the active ingredient PENTAMIDINE ISETHIONATE. This page reproduces the FDA-approved label text so you can check what a product is, who makes it and how it is supplied before discussing it with a pharmacist or prescriber.

What it is used for

Across FDA labelling, products containing PENTAMIDINE ISETHIONATE are most often described in connection with: usage pentam, pentamidine isethionate, injection indicated, treatment pneumonia, due pneumocystis. Wording differs between labels, and the full indications section on this page takes precedence when it is present.

Indications & Usage

INDICATIONS AND USAGE Pentam 300 (pentamidine isethionate for injection) is indicated for the treatment of pneumonia due to Pneumocystis carinii .

Dosage & Administration

DOSAGE AND ADMINISTRATION CAUTION: DO NOT USE SODIUM CHLORIDE INJECTION, USP FOR INITIAL RECONSTITUTION BECAUSE PRECIPITATION WILL OCCUR. Pentamidine isethionate should be administered IM or IV only. The recommended regimen for adults and pediatric patients beyond 4 months of age is 4 mg/kg once a day for 14 to 21 days. Therapy for longer than 21 days with pentamidine isethionate has also been used but may be associated with increased toxicity. Intramuscular Injection The contents of one vial (300 mg) should be dissolved in 3 mL of Sterile Water for Injection, USP at 22° - 30°C (72° - 86°F). The calculated daily dose should then be withdrawn and administered by deep IM injection. Intravenous Injection The contents of one vial (300 mg) should first be dissolved in 3 to 5 mL of Sterile Water for Injection, USP, or 5% Dextrose Injection, USP at 22°- 30°C (72° - 86°F). The calculated dose of pentamidine isethionate should then be withdrawn and diluted further in 50 to 250 mL of 5% Dextrose Injection, USP. The diluted IV solutions containing pentamidine isethionate should be infused over a period of 60 to 120 minutes. Aseptic technique should be employed in preparation of all solutions. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. Stability After reconstitution with sterile water, the Pentam solution is stable for 48 hours in the original vial at room temperature if protected from light. To avoid crystallization,store at 22° - 30°C (72° - 86°F). Intravenous infusion solutions of pentamidine isethionate at 1 mg/mL and 2.5 mg/mL prepared in 5% Dextrose Injection, USP are stable at room temperature for up to 24 hours. Intravenous (IV) solutions of pentamidine isethionate have been shown to be incompatible with fluconazole and foscarnet sodium. IV solutions of pentamidine isethionate have been shown to be compatible with IV solutions of zidovudine (AZT) and diltiazem hydrochloride.

Contraindications

CONTRAINDICATIONS Contraindicated in patients with a history of hypersensitivity to pentamidine isethionate.

Warnings

WARNINGS Fatalities due to severe hypotension, hypoglycemia, acute pancreatitis and cardiac arrhythmias have been reported in patients treated with pentamidine isethionate, both by the IM and IV routes. Severe hypotension may result after a single IM or IV dose and is more likely with rapid IV administration (see PRECAUTIONS ). The administration of the drug should, therefore, be limited to the patients in whom Pneumocystis carinii has been demonstrated. Patients should be closely monitored for the development of serious adverse reactions (see PRECAUTIONS and ADVERSE REACTIONS ). Extravasations have been reported which, in some instances, proceeded to ulceration, tissue necrosis and/or sloughing at the injection site. While not common, surgical debridement and skin grafting has been necessary in some of these cases; long-term sequelae have been reported. Prevention is the most effective means of limiting the severity of extravasation. The intravenous needle or catheter must be properly positioned and closely observed throughout the period of pentamidine isethionate administration. If extravasation occurs, the injection should be discontinued immediately and restarted in another vein. Because there are no known local treatment measures which have proven to be useful, management of the extravasation should be symptomatic.

Adverse Reactions

ADVERSE REACTIONS To report SUSPECTED ADVERSE REACTIONS, contact Fresenius Kabi USA, LLC at 1-800-551-7176 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. CAUTION : Fatalities due to severe hypotension, hypoglycemia, acute pancreatitis and cardiac arrhythmias have been reported in patients treated with pentamidine isethionate, both by the IM and IV routes. Nephrotoxic events (increased creatinine, impaired renal function, azotemia, and renal failure) are common with the parenteral administration of pentamidine isethionate. The administration of the drug should, therefore, be limited to the patients in whom Pneumocystis carinii has been demonstrated. The most frequently reported spontaneous adverse events (1 to 30%) reported in clinical trials, regardless of their relation to pentamidine isethionate therapy were as follows (n=424): Cardiovascular: Hypotension 5.0% Gastrointestinal: Anorexia/Nausea 5.9% Hematologic: Anemia Leukopenia Thrombocytopenia 1.2% 10.4% 2.6% Hepatic: Elevated liver function tests 8.7% Metabolic: Hypoglycemia 5.9% Neurologic: Confusion/hallucinations 1.7% Skin: Sterile abscess and/or necrosis, pain, or induration at the site of IM injection Rash 11.1% 3.3% Special Senses: Bad taste 1.7% Urogenital: Azotemia Elevated serum creatinine Elevated blood urea nitrogen Impaired renal function 8.5% 23.6% 6.6% 28.8% Adverse events with a frequency of less than 1% incidence were as follows (No causal relationship to treatment has been established for these adverse events): Body as a whole: Allergic reaction (i.e. urticaria, itching, rash), anaphylaxis, arthralgia, chills, extrapulmonary pneumocystosis, headache, night sweats, and Stevens-Johnson syndrome. Cardiovascular: Abnormal ST segment of electrocardiogram, cardiac arrhythmias, cerebrovascular accident, hypertension, palpitations, phlebitis, syncope, tachycardia, vasodilatation, vasculitis and ventricular tachycardia. Gastrointestinal: Abdominal pain, diarrhea, dry mouth, dyspepsia, hematochezia, hypersalivation, melena, pancreatitis, splenomegaly, and vomiting. Hematological: Defibrination, eosinophilia, neutropenia, pancytopenia, and prolonged clotting time. Hepatic: Hepatic dysfunction, hepatitis and hepatomegaly Metabolic: Hyperglycemia, hyperkalemia, hypocalcemia, and hypomagnesemia. Neurological: Anxiety, confusion, depression, dizziness, drowsiness, emotional lability, hypesthesia, insomnia, memory loss, neuropathy, nervousness, neuralgia, paranoia, paresthesia, peripheral neuropathy, seizure, tremors, unsteady gait, and vertigo. Respiratory system: Asthma, bronchitis, bronchospasm, chest congestion, chest tightness, coryza, cyanosis, eosinophilic or interstitial pneumonitis, gagging, hemoptysis, hyperventilation, laryngitis, laryngospasm, non-specific lung disorder, nasal congestion, pleuritis, pneumothorax, rales, rhinitis, shortness of breath, and tachypnea. Skin: Desquamation, dry and breaking hair, dry skin, erythema, dermatitis, pruritus, rash, and urticaria. Special senses: Blepharitis, blurred vision, conjunctivitis, contact lens discomfort, eye pain or discomfort, loss of hearing, loss of taste, and loss of smell. Urogenital: Flank pain, hematuria, incontinence, nephritis, renal dysfunction and renal failure. From post-marketing clinical experience with pentamidine isethionate, the following adverse events have been reported: cough, diabetes mellitus/ketoacidosis, dyspnea, infiltration (extravasation–see WARNINGS ), and torsades de pointes.

More products with the same ingredient

PENTAMIDINE ISETHIONATE

Pentamidine Isethionate

PAI Holdings, LLC dba PAI Pharma View label

Pentamidine Isethionate

PAI Holdings, LLC dba PAI Pharma View label

How products containing PENTAMIDINE ISETHIONATE compare

FDA lists 3 drug label records with PENTAMIDINE ISETHIONATE as the active ingredient. The most common dosage forms and the manufacturers with the most records are summarised below; strengths, pack sizes and inactive ingredients can still differ between apparently similar products.

Dosage formProductsManufacturerProducts
— — PAI Holdings, LLC dba PAI Pharma 2
— — Fresenius Kabi USA, LLC 1
— — — —
— — — —
— — — —

Recall and safety notices

5 FDA recall record(s) match this product name or manufacturer. A match means the firm or product name appears in the enforcement report; confirm lot numbers and dates against the official FDA notice before acting.

RecallProductFirmClassStatusReported
D-0827-2026 Tyenne (tocilizumab-aazg) Injection, 400 mg/20 mL (20 mg/mL), 20 mL vial, Rx Only, Manufactured by Fresenius Kabi USA, LLC, Lake Zurich, Illinois, 60047, NDC 65219-594-20. Fresenius Kabi USA, LLC Class I Ongoing 20260902
D-0788-2026 Morphine Sulfate Injection, USP, 2 mg /mL, 1 mL single-dose Simplist prefilled syringes, For Intramuscular or Intravenous use, Rx only, Fresenius Kabi, Lake Zurich, IL. Unit of Use NDC Number 76045-004-01; Unit of Sale NDC Number 76045-004-11 Fresenius Kabi USA, LLC Class I Ongoing 20260826
D-0727-2026 Naropin (ropivacaine hydrochloride Injection, USP), 0.5%, 100 mg per 20 mL (5 mg per mL), Twenty-five, 20 mL Single-Dose Vials, Rx only, Fresenius Kabi, Lake Zurich, IL 60047 NDC Tray: 63323-286-23; NDC Vial: 63323-286-05 Fresenius Kabi USA, LLC Class II Ongoing 20260729
D-0726-2026 Lidocaine HCl Injection, USP, 2%, 100 mg per 5 mL (20 mg per mL), 25 Single Dose Vials, 5 mL per vial, Rx only, Sterile, Fresenius Kabi, Lake Zurich, IL 60047 NDC Tray: 63323-208-05; NDC Vial: 63323-208-01 Fresenius Kabi USA, LLC Class II Ongoing 20260729
D-0728-2026 Xylocaine (lidocaine HCl Injection, USP), 1%, 200 mg per 20 mL (10 mg per mL), 25 Multiple-Dose Vials, 20 mL, Rx only, Sterile, Fresenius Kabi, Lake Zurich, IL 60047 NDC Tray: 63323-485-27; NDC Vial: 63323-485-01 Fresenius Kabi USA, LLC Class II Ongoing 20260729

Frequently asked questions

What is Pentam 300 used for?
INDICATIONS AND USAGE Pentam 300 (pentamidine isethionate for injection) is indicated for the treatment of pneumonia due to Pneumocystis carinii .

Who makes Pentam 300?
Fresenius Kabi USA, LLC is the labeler of record for Pentam 300. 3 FDA label records share the active ingredient PENTAMIDINE ISETHIONATE, so generic and branded versions may come from different companies; the manufacturer named on your pack is the one that matters for any enquiry.

What form does Pentam 300 come in?
administered by intramuscular. Strengths and pack sizes vary by label, so compare the NDC on your pack with the identifier listed on this page.

Is Pentam 300 prescription or over-the-counter?
The FDA label for this product is recorded as human prescription drug. Marketing status can differ between strengths and countries, so check the dispensing rules where you live.

Are there other products containing PENTAMIDINE ISETHIONATE?
Yes. 3 FDA drug label records list PENTAMIDINE ISETHIONATE as the active ingredient. Products with the same active ingredient can usually be substituted only when a prescriber or pharmacist confirms it is appropriate.

Has Pentam 300 been recalled?
5 FDA recall record(s) match this product name or manufacturer. Review the recall and safety notices section on this page and confirm lot numbers against the official FDA enforcement report.

Where does this information come from?
All content is reproduced from FDA Structured Product Labelling data via openFDA. It is provided for identification and reference only and is not medical advice.

This page reproduces FDA Structured Product Labelling data for identification and reference. It is not medical advice, does not diagnose or treat any condition, and does not sell or price any medicine.