OCTREOSCAN
OCTREOSCAN is an FDA drug label for the active ingredient INDIUM IN -111 PENTETREOTIDE manufactured by Curium US LLC. This page reproduces the FDA-approved indications and usage, dosage, contraindications, warnings, and adverse reactions exactly as published in the drug label. Data source: openFDA (U.S. FDA), label effective 20220221.
- Generic name
- INDIUM IN -111 PENTETREOTIDE
- Manufacturer
- Curium US LLC
- Product type
- HUMAN PRESCRIPTION DRUG
- Route
- N/A
- Dosage form
- N/A
- NDC
- 69945-050
- Application
- NDA020314
- Label effective
- 20220221
About this product
OCTREOSCAN is an FDA-registered drug product whose active ingredient is INDIUM IN -111 PENTETREOTIDE. It is labelled by Curium US LLC and marketed as a human prescription drug product. Identifiers on file: NDC 69945-050, application NDA020314, label effective 20220221. This page reproduces the FDA-approved label text so you can check what a product is, who makes it and how it is supplied before discussing it with a pharmacist or prescriber.
What it is used for
Across FDA labelling, products containing INDIUM IN -111 PENTETREOTIDE are most often described in connection with: usage octreoscan, radiolabeling agent, scintigraphic localization, metastatic neuroendocrine, tumors bearing, somatostatin receptors. Wording differs between labels, and the full indications section on this page takes precedence when it is present.
Indications & Usage
INDICATIONS AND USAGE Octreoscan, after radiolabeling, is an agent for the scintigraphic localization of primary and metastatic neuroendocrine tumors bearing somatostatin receptors.
Dosage & Administration
DOSAGE AND ADMINISTRATION Before administration, a patient should be well hydrated. After administration, the patient must be encouraged to drink fluids liberally. Elimination of extra fluid intake will help reduce the radiation dose by flushing out unbound, labelled pentetreotide by glomerular filtration. It is also recommended that a mild laxative (e.g., bisacodyl or lactulose) be given to the patient starting the evening before the radioactive drug is administered, and continuing for 48 hours. Ample fluid uptake is necessary during this period as a support both to renal elimination and the bowel-cleansing process. In a patient with an insulinoma, bowel-cleansing should be undertaken only after consultation with an endocrinologist. The recommended intravenous dose for planar imaging is 111 MBq (3 mCi) of Indium In 111 Pentetreotide Injection prepared from an Octreoscan kit. The recommended intravenous dose for SPECT imaging is 222 MBq (6 mCi) of Indium In 111 Pentetreotide Injection. The dose should be confirmed by a suitably calibrated radioactivity ionization chamber immediately before administration. As with all intravenously administered products, Octreoscan should be inspected visually for particulate matter and discoloration prior to administration, whenever solution and container permit. Preparations containing particulate matter or discoloration should not be administered. They should be disposed of in a safe manner, in compliance with applicable regulations. Aseptic techniques and effective shielding should be employed in withdrawing doses for administration to patients. Waterproof gloves should be worn during the administration procedure. Do not administer Octreoscan in TPN solutions or through the same intravenous line. Radiation Dosimetry The estimated radiation doses Values listed include a correction for a maximum of 0.1% indium In-114m radiocontaminant at calibration. to the average adult (70 kg) from intravenous administration of 111 MBq (3 mCi) and 222 MBq (6 mCi) are presented in Table 4. These estimates were calculated by Oak Ridge Associated Universities using the data published by Krenning, et al. E.P. Krenning, W.H. Bakker, P.P.M. Kooij, W.A.P. Breeman, H.Y. Oei, M. de Jong, J.C. Reubi, T.J. Visser, C. Bruns, D.J. Kwekkeboom, A.E.M. Reijs, P.M. van Hagen, J.W. Koper, and S.W.J. Lamberts, “Somatostatin Receptor Scintigraphy with Indium-111-DTPA-D-Phe-1-Octreotide in Man: Metabolism, Dosimetry and Comparison with Iodine-123-Try-3-Octreotide,” The Journal of Nuclear Medicine, Vol. 33, No. 5, May 1992, pp. 652-658. Table 4. Estimated Absorbed Radiation Doses after Intravenous Administration of Indium In 111 Pentetreotide Assumes 4.8 hour voiding interval and International Commission on Radiological Protection (ICRP) 30 model for the gastrointestinal tract calculations. to a 70 kg Patient PLANAR SPECT Organ mGy/111 MBq rads/3 mCi mGy/222 MBq rads/6 mCi Kidneys 54.16 5.42 108.32 10.83 Liver 12.15 1.22 24.31 2.43 Spleen 73.86 7.39 147.73 14.77 Uterus 6.34 0.63 12.67 1.27 Ovaries 4.89 0.49 9.79 0.98 Testes 2.90 0.29 5.80 0.58 Red Marrow 3.46 0.35 6.91 0.69 Urinary Bladder Wall 30.24 3.02 60.48 6.05 GI Tract Stomach Wall 5.67 0.57 11.34 1.13 Small Intestine 4.78 0.48 9.56 0.96 Upper Large Intestine 5.80 0.58 11.59 1.16 Lower Large Intestine 7.73 0.77 15.46 1.55 Adrenals 7.55 0.76 15.11 1.51 Thyroid 7.43 0.74 14.86 1.49 mSv/111 MBq rem/3 mCi mSv/222 MBq rem/6 mCi Effective Dose Estimated according to ICRP Publication 53. Equivalent 13.03 1.30 26.06 2.61
Contraindications
CONTRAINDICATIONS None known.
Warnings
WARNINGS DO NOT ADMINISTER IN TOTAL PARENTERAL NUTRITION (TPN) ADMIXTURES OR INJECT INTO TPN INTRAVENOUS ADMINISTRATION LINES; IN THESE SOLUTIONS, A COMPLEX GLYCOSYL OCTREOTIDE CONJUGATE MAY FORM. The sensitivity of scintigraphy with indium In 111 pentetreotide may be reduced in patients concurrently receiving therapeutic doses of octreotide acetate. Consideration should be given to temporarily suspending octreotide acetate therapy before the administration of Indium In 111 Pentetreotide Injection and to monitoring the patient for any signs of withdrawal. Hypersensitivity reactions following administration of somatostatin receptor imaging agents predominantly consisted of cutaneous reactions such as rash and pruritus. Reactions reversed either spontaneously or with routine symptomatic management. Less frequently hypersensitivity reactions included angioedema or cases with features of anaphylaxis.
Adverse Reactions
ADVERSE REACTIONS The following adverse effects were observed in clinical trials at a frequency of less than 1% of 538 patients: dizziness, fever, flush, headache, hypotension, changes in liver enzymes, joint pain, nausea, sweating, and weakness. These adverse effects were transient. Also in clinical trials, there was one reported case of bradycardia and one case of decreased hematocrit and hemoglobin. Pentetreotide is derived from octreotide which is used as a therapeutic agent to control symptoms from certain tumors. The usual dose for Indium In 111 Pentetreotide Injection is approximately 5 to 20 times less than for octreotide and is subtherapeutic. The following adverse reactions have been associated with octreotide in 3% to 10% of patients: nausea, injection site pain, diarrhea, abdominal pain/discomfort, loose stools, and vomiting. Hypertension and hyper- and hypoglycemia have also been reported with the use of octreotide. The following adverse reactions have been identified during postapproval use of Octreoscan. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Immune System Disorders: Hypersensitivity reactions, predominantly rash, pruritus, less frequently angioedema or features of anaphylaxis.
Frequently asked questions
What is OCTREOSCAN used for?
INDICATIONS AND USAGE Octreoscan, after radiolabeling, is an agent for the scintigraphic localization of primary and metastatic neuroendocrine tumors bearing somatostatin receptors.
Who makes OCTREOSCAN?
Curium US LLC is the labeler of record for OCTREOSCAN.
Is OCTREOSCAN prescription or over-the-counter?
The FDA label for this product is recorded as human prescription drug. Marketing status can differ between strengths and countries, so check the dispensing rules where you live.
Has OCTREOSCAN been recalled?
No FDA recall record in our database matches this product name or manufacturer. Recall data is updated periodically, so a very recent notice may not appear here yet.
Where does this information come from?
All content is reproduced from FDA Structured Product Labelling data via openFDA. It is provided for identification and reference only and is not medical advice.
This page reproduces FDA Structured Product Labelling data for identification and reference. It is not medical advice, does not diagnose or treat any condition, and does not sell or price any medicine.